The following specifications describe a forced air circulation drying oven for high‑temperature applications up to 500°C. Model MSLTWG-5050LSWISS is part of the MASTER SCIENCE LTWG Series. All performance data are based on factory testing under standard conditions.
Model number: MSLTWG-5050LSWISS
Maximum operating temperature: 500°C (also suitable for 400°C, 600°C and below depending on configuration)
Interior material: 304 hairline brushed stainless steel
Interior design: arc angle corners for easy cleaning
Exterior material: high‑quality steel plate
Heating element: 304 stainless steel heating tube
Air circulation: blower installed on top surface of chamber with internal air duct for forced convection
Temperature control system: intelligent microcomputer integrated PID logic operation
Display: color LCD screen with digital readout
Control functions: set temperature, constant temperature, timing, self‑tuning, over‑temperature alarm
Additional features: incoming call recovery function, sensor self‑diagnosis, over‑temperature alarm
Door mechanism: inverted door lock, automatically locks when closed, good sealing and easy to open
Mobility: four casters with lock switch for easy positioning
The features above translate into measurable improvements for any lab performing drying, baking, sintering, curing, heat treatment, or high‑temperature testing. Each point below connects a specification to a practical outcome.
Superior temperature uniformity for consistent results – The blower mounted on the top surface, combined with an internal air duct, forces hot air to circulate regularly throughout the chamber. This eliminates cold spots and temperature gradients. Samples placed on different shelves receive the same heat exposure, so batch‑to‑batch variation drops significantly.
Accurate PID control with visual feedback – The intelligent microcomputer integrated system uses PID logic for precise temperature regulation. The color LCD screen shows set temperature, actual temperature, and constant temperature status at a glance. Self‑tuning function adjusts parameters automatically, so operators do not need to be control engineers.
Safe unattended operation – Over‑temperature alarm triggers when the chamber exceeds safe limits. Sensor self‑diagnosis alerts the user before a faulty probe ruins a run. Incoming call recovery means the oven restarts automatically after a power interruption with the last settings. Researchers can start a 24‑hour heat treatment at 5 PM and return the next morning without worry.
Easy cleaning and corrosion resistance – The 304 stainless steel inner tank resists rust and chemical attack from sample outgassing. The arc angle design leaves no sharp corners where residues accumulate. A quick wipe with a suitable solvent cleans the chamber in minutes, not hours.
Secure door sealing with one‑hand operation – The inverted door lock automatically engages when the door closes. No separate latch or clamp to tighten. Sealing is consistent every time, reducing heat loss and improving energy efficiency. Opening is equally simple, even while wearing heat‑resistant gloves.
Pain point: Uneven heating ruins expensive samples.
Some ovens have poor air circulation, leaving the top shelf 30°C hotter than the bottom. The MASTER SCIENCE MSLTWG-5050LSWISS high temperature drying oven (a forced air circulation model with a top‑mounted blower and internal duct) pushes heated air through a designed pathway, ensuring temperature variation stays within tight limits. Ceramic sintering, glass annealing, and electronic component curing all succeed across the entire chamber.
Pain point: Control panels that are difficult to read and program.
Small monochrome displays with cryptic codes frustrate operators and lead to setpoint errors. The same MASTER SCIENCE MSLTWG-5050LSWISS high temperature drying oven (with a color LCD screen and PID logic) shows all parameters in clear digital text. Set temperature, real temperature, timer value, and alarm status appear on one screen. Programming a multi‑step profile takes seconds, not guesswork.
Pain point: Cleaning baked‑on residues from sharp interior corners.
Square‑cornered chambers trap carbonised material that requires scraping and abrasive cleaners. The MASTER SCIENCE MSLTWG-5050LSWISS high temperature drying oven (featuring arc angle 304 stainless steel interior) eliminates sharp corners. Wiping with a damp cloth follows the smooth curve, removing residues completely. The brushed finish also resists scratching, keeping the chamber clean for sensitive applications.
Pain point: Heat loss and poor sealing at the door.
Door seals degrade over time, causing temperature drift and higher electricity bills. The MASTER SCIENCE MSLTWG-5050LSWISS high temperature drying oven (with an inverted door lock that automatically self‑seals) ensures consistent compression of the gasket every time the door closes. No manual adjustment. No gradual leakage. The lock also provides a firm grip, preventing accidental opening during operation.
Pain point: Moving a heavy oven for cleaning or reconfiguration.
Once placed, most ovens never move because they lack wheels. The MASTER SCIENCE MSLTWG-5050LSWISS high temperature drying oven (equipped with four lockable casters) rolls easily across the laboratory floor. Push it aside for deep cleaning of the bench or pull it out to access rear vents. The lock switch then holds it firmly in position during use. No lifting, no strain.
Industrial quality control laboratories testing electronic components, polymers, and composites use the oven for heat exposure tests, accelerated aging, and moisture removal before weighing.
Pharmaceutical and medical device laboratories use the oven for sterilisation of glassware (dry heat), stability testing of drug substances at elevated temperatures, and curing of coatings on medical instruments.
University research laboratories in materials science, chemistry, and engineering use the oven for synthesis of ceramics, drying of precipitates, annealing of thin films, and thermal decomposition studies.
Clinical and diagnostic laboratories use the oven for drying pathological specimens, heat treatment of culture media, and decontamination of contaminated glassware.
Small manufacturing facilities producing printed circuit boards, rubber seals, or advanced composites use the oven for post‑curing, baking out moisture from components, and testing heat resistance of finished goods.
The oven stands on four casters. Two casters have locks. The user pushes the oven to the desired location, engages the locks, and connects to the appropriate power outlet. The color LCD screen illuminates when powered on. The operator sets the target temperature using the keypad or touch interface (depending on the specific LTWG variant). The PID controller begins heating. The blower starts automatically, circulating air through the internal duct.
Once the set temperature is reached, the display indicates constant temperature status. The timer can be set from minutes to days. At the end of the timed run, the heating stops but the blower may continue to cool the chamber (check factory settings). The over‑temperature alarm is set separately, typically 10‑20°C above the setpoint.
The inverted door lock: to open, lift the handle slightly. The lock releases. To close, push the door shut until the lock clicks. No additional force needed.
Cleaning: allow the oven to cool below 100°C. Remove shelves. Wipe the interior 304 stainless steel surfaces with a non‑abrasive cloth and mild detergent or solvent appropriate for the residue. The arc angles prevent buildup at corners.
The MSLTWG-5050LSWISS ships with:
Main oven body with 304 stainless steel interior and exterior steel shell
Top‑mounted blower and internal air duct
304 stainless steel heating element
PID microcomputer controller with color LCD screen
Inverted door lock mechanism
Four casters (two locking)
One or two stainless steel shelves (confirm with supplier)
Power cord
User manual and calibration certificate
Optional accessories may include additional shelves, shelf brackets, a programmable multi‑segment controller, or a data logging port (RS485/USB). Contact us for availability.
The customer should specify the required voltage and plug type when ordering, as the datasheet does not list power requirements. Typical options are 220V/50Hz or 110V/60Hz.
Optimum Solution is a leading supplier of laboratory equipment, analytical instruments, and process control solutions in Bangladesh. Since our inception, we have built a strong presence in the industry, serving research labs, universities, pharmaceutical companies, and quality control laboratories nationwide. Through continuous dedication to improving our products and services, Optimum Solution has earned the trust and loyalty of our valued clients.